E 2.2.1 Report on the Pilot Experience for the Recovery of P Salts in an Urban Setting

Summary

The report analyses phosphorus recovery through precipitation from dewatering liquor generated at an urban wastewater treatment plant (WWTP), combining simulations, laboratory tests and pilot plant trials. The wastewater stream presented favourable conditions for phosphorus salt formation; however, its variability, organic load and solids content made process control and precipitate separation more challenging. The trials demonstrated that phosphorus can be precipitated using the components naturally present in the dewatering liquor. Increasing the pH to 10 improved performance, while combining pH adjustment with aeration reduced the average caustic soda consumption to 0.51 L NaOH/m³ of dewatering liquor, although it also generated foam and turbidity. Nevertheless, aeration did not lead to a significant improvement in phosphorus recovery. The addition of Ca(OH)₂ promoted the formation of calcium phosphates and increased the presence of hydroxyapatite. At a molar Ca:P ratio of 2:1, an average phosphate removal rate of 80.2 ± 5.2% was achieved, whereas reducing the ratio to 1.5:1 decreased the average removal rate to 61.7 ± 11.6%, although it also reduced calcium reagent consumption. Furthermore, adding Ca(OH)₂ alone, without NaOH, did not guarantee sufficiently alkaline conditions to maximise precipitation. Despite the high phosphorus removal rates achieved, the main process limitation was the effective recovery of the salts, due to the formation of fine particles and filter clogging. Prior sedimentation and the use of filter bags with larger pore sizes improved operation; however, increasing phosphorus recovery will require incorporating a pre-treatment stage to reduce the solids load in the incoming stream and optimising the filtration system. During Experiment 3, the maximum salt recovery was achieved, reaching 55 g/m³ of dewatering liquor, with a phosphorus content of 8.61%, at pH 10 and a molar Ca:P ratio of 2:1. This stage also achieved the highest theoretical phosphorus removal rate (80.2%) and the highest actual recovery efficiency (8.60%). Overall, the pilot plant confirms the potential of this technology for phosphorus recovery while reducing NaOH and Ca(OH)₂ consumption. Scaling up the process will require controlling the variability of the dewatering liquor, adjusting the Ca:P ratio, and improving sedimentation, filtration and conditioning stages for the recovered product.

Description